GMCC DZ100V1A Inverter Refrigerator Compressor R600a

  Remaining 5 only

GMCC DZ100V1A R600a inverter refrigerator compressor, label-rated 45–200V and 36–144Hz. Matching electronic controller required.

 more information

SAR 400.00

+  

Earn loyalty points with this purchase

Rewards  

product sku

CO-DZ100V1A

Weight

5.0 kg

Quantity

This product is out of stock

Notify me when product is available

share product

product description

GMCC DZ100V1A Inverter Refrigerator Compressor R600a 3-Phase

Hermetic GMCC inverter refrigeration compressor intended for compatible R600a refrigerator cooling systems. It compresses and circulates refrigerant under control of a matching electronic inverter controller. Do not connect directly to household AC mains.

Features and Functions

  • Variable-speed inverter operation according to cooling demand.
  • Hermetic steel shell, mounting feet and copper tube connections.
  • Replacement use requires exact matching of compressor, inverter driver, cooling performance and system connections.

Technical Specifications

  • Brand: GMCC
  • Model: DZ100V1A
  • Refrigerant: R600a (flammable)
  • Voltage marked on unit: 45–200V
  • Operating frequency marked: 36–144Hz
  • Drive: electronic inverter, 3-phase
  • Label statement: 3PH electronic control

Application & Compatibility

For R600a refrigeration systems designed for this compressor. Confirm the exact appliance model, inverter controller, voltage/frequency range, mounting and copper tubing before purchasing. Compatibility with particular refrigerator models is not confirmed.

⚠️ Operational Warranty & Pre-Brazing Inspection

⚡ A qualified refrigeration technician must electrically check and assess the compressor's pressure performance before brazing, using a compatible inverter controller and suitable test equipment. Do not connect the compressor directly to household mains.

🔍 If a manufacturing defect is suspected before brazing, stop installation and contact EMTEDAD with evidence of the fault for inspection and applicable return handling, subject to store policy and statutory rights.

🛠️ After a successful pre-installation check, the technician is responsible for correct brazing, wiring, evacuation, charging and commissioning, and for damage caused by installation errors. A successful check does not waive statutory rights concerning a later-proven manufacturing defect.

🔥 R600a is flammable. Refrigeration work must be performed by trained personnel following appropriate safety procedures.

EMTEDAD Air Conditioning & Cooling Co. Ltd. – Experience since 1982.